火电储能联合调频系统的协调控制与性能优化

Coordinated Control and Performance Optimization of Thermal Power Energy Storage Combined Frequency Regulation System

  • 摘要: 针对火电机组调频响应滞后、爬坡速率不足、储能系统容量有限、孤网运行稳定性欠佳等问题,文章设计了基于协调控制策略的联合调频试验方案。选取某600 MW火电机组与10 MW/20 MWh锂电池储能系统为试验对象,搭建联合调频试验平台,开展静态、动态及对比试验,验证协调控制策略有效性。试验表明,各项指标均满足电网调频考核标准。

     

    Abstract: A joint frequency regulation test scheme based on coordinated control strategy is designed in this article to address the problems of lagging frequency regulation response, insufficient climbing speed, limited energy storage system capacity, and poor stability of isolated network operation in thermal power units. Select a 600 MW thermal power unit and a 10 MW/20 MWh lithium battery energy storage system as the test objects, build a joint frequency regulation test platform, conduct static, dynamic, and comparative tests, and verify the effectiveness of the coordinated control strategy. The experiment shows that all indicators meet the assessment standards for power grid frequency regulation.

     

/

返回文章
返回